Visit the TopView Forum

Current release: 6.7.0

Download

Free TopView evaluation

TopView demonstration videos
Features - Alarms & Limits

Customers/Testimonials

TopView Versions

Version Overview

Requirements

TopView OPC/SCADA

TopView PI

TopView PerfMon

TopView Features

General

Configure & Manage

Alarm/Event Detection
Audible & Notification
 2-Way Email/SMS
Alarm Logs/SQL Server
Alarm Reports

HTML Snapshot Reports
Remote Access

Pictorial Overviews

TopView OPC/SCADA, PI

TopView PerfMon

Components

Overview

Configurator

TopView Window

Admin Tools

Information Icon

 Remote Viewer

 

More information...

Customers/Testimonials

Product Data sheet

Pricing / Quotes
Distributors

 

Free product videos
TopView Forum

 

Modems and Voice cards

Additional Resources

 

 

 

 

 

 

 

 

Alarm/Event Detection

TopView's alarm condition and limit settings allow the user to detect a wide range of events based on tag values, tag status, tag timestamps and state (acknowledged, in alarm). With configurable delays and deadbands, the user can finely tune the alarm event detection logic in TopView.

  • Configurable value, value status (good, bad, OPC uncertain, PI questionable), timestamp-age, value flat-line, and value-change alarm conditions

  • Optional delay of alarm unless condition is TRUE for a period of time

  • Optional delay of return to normal unless alarm condition is FALSE for a period of time

  • Optional expire of alarm after a period of time

  • Optional alarm limit dead bands for alarm hysteresis

  • Optional alarm limit blackout period to filter frequent alarms

  • Alarm and point priorities

  • Complex alarm conditions involving multiple tags/points and conditions

  • Flexible alarm limit scheduling (days-per-week and times-per-day)

  • Custom alarm and return to normal messages with placeholders for point values,  timestamps, time of alarm, ...

  • Fixed and dynamic limits (use other tag/point values as limits)

  • Storage of user comments to document each set of alarm limits

  • Ability to temporarily set alarm conditions inactive

  • Ability to suppress alarm detection if associated equipment not running

  • Output points (write to tags) upon alarm, return-to-normal, and alarm acknowledgement events

  • Configurable blackout periods for startup alarms

  • Ability to automate configuration changes to tags, alarm conditions, and alarm limits through scripts or custom code

 


The EXELE logo, ProcessTemplates, EDICT, and EDICTvb are trademarks of Exele Information Systems, Inc.
TopView
® and OPCcalc®  are registered trademarks of EXELE Information Systems, Inc.
All other trademarks are the property of their respective owners.

Copyright © 2010 EXELE Information Systems, Inc.

Contact support@exele.com